SolaRay
SRCC OG-300 System Ratings |
|
The Solar Rating & Certification Corporation OG-300
systems level rating is an independent assessment of both system
reliability and performance. Systems that receive this rating must
meet HUD minimum property standards in addition to a rigorous review
performed by SRCC staff and design review team. Once the system has
passed these quality assurance checks it undergoes a full performance
analysis to estimate the actual solar contribution of the system towards
an average hot water load. This contribution, as defined by the
Solar Energy Factor is listed alongside the different variants of each
system type.
The SRCC provides the following description for
SunEarth SolaRay Systems:
Glazed
Flat-Plate Collector, Differential Controller, Tank Wrap Around Heat
Exchanger With
Double Wall And Positive Leak Detection, No Load Side Heat Exchanger, Fluid Class
II,
Freeze Tolerance -28 F.
|
|
|
|
|
|
AC Pump Option -
Electric Backup
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE32P-80-1 |
1993-001A |
EP-32 |
32.8 |
80 |
N/A |
1.7 |
| TE32C-80-1 |
1993-001B |
EC-32 |
32.8 |
80 |
N/A |
1.8 |
| TE40P-80-1 |
1993-001C |
EP-40 |
40.8 |
80 |
N/A |
2.0 |
| TE40C-80-1 |
1993-001D |
EC-40 |
40.8 |
80 |
N/A |
2.1 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE32P-80-2 |
1996-001A |
EP-32 |
32.8 |
80 |
50 |
1.5 |
| TE32C-80-2 |
1996-001B |
EC-32 |
32.8 |
80 |
50 |
1.6 |
| TE40P-80-2 |
1996-001C |
EP-40 |
40.8 |
80 |
50 |
1.8 |
| TE40C-80-2 |
1996-001D |
EC-40 |
40.8 |
80 |
50 |
1.8 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE48P-80-1 |
1993-001K |
EP-24 |
49.1 |
80 |
N/A |
2.3 |
| TE48C-80-1 |
1993-001L |
EC-24 |
49.1 |
80 |
N/A |
2.5 |
| TE64P-80-1 |
1993-001G |
EP-32 |
65.6 |
80 |
N/A |
3.3 |
| TE64C-80-1 |
1993-001H |
EC-32 |
65.6 |
80 |
N/A |
3.9 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE48P-80-2 |
1996-001I |
EP-24 |
49.1 |
80 |
50 |
2.0 |
| TE48C-80-2 |
1996-001J |
EC-24 |
49.1 |
80 |
50 |
2.1 |
| TE64P-80-2 |
1996-001E |
EP-32 |
65.6 |
80 |
50 |
2.6 |
| TE64C-80-2 |
1996-001F |
EC-32 |
65.6 |
80 |
50 |
3.0 |
|
|
|
AC Pump Option - Gas
Backup
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE40P-80-2G |
2001-001A |
EP-40 |
40.8 |
80 |
50 |
1.0 |
| TE40C-80-2G |
2001-001B |
EC-40 |
40.8 |
80 |
50 |
1.0 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE48P-80-2G |
2001-001C |
EP-24 |
49.1 |
80 |
50 |
1.1 |
| TE48C-80-2G |
2001-001D |
EC-32 |
49.1 |
80 |
50 |
1.1 |
| TE64P-80-2G |
2001-001E |
EP-32 |
65.6 |
80 |
50 |
1.3 |
| TE64C-80-2G |
2001-001F |
EC-32 |
65.6 |
80 |
50 |
1.4 |
|
|
|
PV Pump Option - Electric
Backup
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE40P-80-1-PV |
2000-004D |
EP-40 |
40.8 |
80 |
N/A |
1.9 |
| TE40C-80-1-PV |
2000-004A |
EC-40 |
40.8 |
80 |
N/A |
2.0 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE40P-80-2-PV |
2000-003A |
EP-40 |
40.8 |
80 |
50 |
1.7 |
| TE40C-80-2-PV |
2000-003D |
EC-40 |
40.8 |
80 |
50 |
1.8 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE48P-80-1-PV |
2000-004G |
EP-24 |
49.1 |
80 |
N/A |
2.2 |
| TE48C-80-1-PV |
2000-004H |
EC-24 |
49.1 |
80 |
N/A |
2.3 |
| TE64P-80-1-PV |
2000-004E |
EP-32 |
65.6 |
80 |
N/A |
2.9 |
| TE64C-80-1-PV |
2000-004B |
EC-32 |
65.6 |
80 |
N/A |
3.3 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE48P-80-2-PV |
2000-003G |
EP-24 |
49.1 |
80 |
50 |
1.9 |
| TE48C-80-2-PV |
2000-003H |
EC-24 |
49.1 |
80 |
50 |
2.0 |
| TE64P-80-2-PV |
2000-003E |
EP-32 |
65.6 |
80 |
50 |
2.4 |
| TE64C-80-2-PV |
2000-003B |
EC-32 |
65.6 |
80 |
50 |
2.6 |
|
|
|
PV Pump Option - Gas Backup
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE40P-80-2G-PV |
2000-003D |
EP-40 |
40.8 |
80 |
50 |
1.0 |
| TE40C-80-2G-PV |
2000-003A |
EC-40 |
40.8 |
80 |
50 |
1.0 |
|
|
|

|
| System
Model |
Cert
300-# |
Collector
Model |
Panel
Area
(sq. ft.) |
Solar
Tank
Volume (gal) |
Auxiliary
Tank Volume (gal) |
SEF |
| TE48P-80-2G-PV |
2001-003G |
EP-24 |
49.1 |
80 |
50 |
1.0 |
| TE48C-80-2G-PV |
2001-003H |
EC-24 |
49.1 |
80 |
50 |
1.1 |
| TE64P-80-2G-PV |
2001-003C |
EP-32 |
65.6 |
80 |
50 |
1.2 |
| TE64C-80-2G-PV |
2001-003D |
EC-32 |
65.6 |
80 |
50 |
1.3 |
|
|
|
Diagrams Courtesy SRCC
|
SRCC is a registered trademark of the Solar Rating &
Certification Corporation
|