THE SUNWISE SERIES

|
Width Inches | Length Inches | Depth Inches | Gross Area Sq Ft | Net Aperture Sq Ft | Dry Weight Lbs. | Fluid Cap. U.S. Gal. | Design Flow Rate GPM |
Press. Drop at Design Flow Rate |
Max Flow Rate GPM | Max. Oper. Press. PSIG | Std Header Width, Inches | Std Header Dia, Inches Nom. | Header, Center to Center, Inches | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SC/SP20 | 36 1/8 | 78 1/4 | 3 1/4 | 19.70 | 17.30 | 60 | .60 | .51 | .015 | 12 | 160 | 39 3/4 | 1 | 73 1/2 | |
| SC/SP21 | 40 | 76 | 3 1/4 | 21.11 | 18.70 | 70 | .70 | .55 | .016 | 12 | 160 | 43 3/8 | 1 | 71 1/4 | |
| SC/SP24 | 36 1/8 | 98 1/4 | 3 1/4 | 24.61 | 21.88 | 80 | .78 | .62 | .017 | 12 | 160 | 39 3/4 | 1 | 93 5/8 | |
| SC/SP32 | 48 1/8 | 98 1/4 | 3 1/4 | 32.79 | 29.81 | 106 | 1.00 | .83 | .018 | 12 | 160 | 51 3/8 | 1 | 93 5/8 | |
| SC/SP40 | 48 1/8 | 122 1/4 | 3 1/4 | 40.81 | 37.33 | 141 | 1.20 | 1.04 | .020 | 12 | 160 | 51 3/8 | 1 | 115 5/8 |
MODEL SC THERMAL PERFORMANCE RATINGS* MODEL SP
| Inch-Pound Units | Inch-Pound Units | |||||||
|---|---|---|---|---|---|---|---|---|
| Btu/ft2/Day | Btu/ft2/Day | |||||||
| Category (Ti-Ta) Ti=inlet fluid temp Ta=ambient air temp | Clear Day 2000 Btu/ft²/Day | Mildly Cloudy Day 1500 Btu/ft²/Day | Cloudy Day 1000 Btu/ft²/Day |
Category (Ti-Ta) Ti=inlet fluid temp Ta=ambient air temp |
Clear Day 2000 Btu/ft²/Day | Mildly Cloudy Day 1500 Btu/ft²/Day | Cloudy Day 1000 Btu/ft²/Day | |
| A(-9°F) | 1,332 | 1,005 | 680 | A(-9°F) | 1,284 | 971 | 659 | |
| B(9°F) | 1,218 | 890 | 565 | B(9°F) | 1,169 | 854 | 542 | |
| C(36°F) | 1,040 | 720 | 402 | C(36°F) | 984 | 677 | 372 | |
| D(90°F) | 699 | 405 | 127 | D(90°F) | 619 | 343 | 89 | |
| E(144°F) | 390 | 137 | - | E(144°F) | 280 | 62 | - | |
-A-Pool
Heating (Warm Climate) B-Pool Heating C-Water Heating (Warm Climate) D-Water
Heating (Cool Climate) E-Air Conditioning/Industrial Process Heat.
Thermal
performance is obtained by multiplying the collector output for the appropriate
application and insolation level by the total gross collector area.
*Collector ratings are derived from the Solar Rating & Certification Corp (SRCC) Document RM-1 and Standard OG-100.
The following shall be the specifications for the solar
collectors. Collectors shall be SunEarth SunWise model ________, and shall be of
the glazed liquid flat plate type. Collectors shall be tested in conformance
with ASHRAE 93-1986, and SRCC 100-81. The collectors also shall be certified by
the SRCC and the Florida Solar Energy Center (FSEC).
The dimensions of the collector shall be _________ inches
in length, _________ inches in width and 3 ¼ inches in depth. The collector
casing shall be an aluminum extrusion (alloy 6063 T5), minimum thickness .060
inch. The casing shall have notched framewalls for ease of plate removal and
reinstallation. Sheet metal screwed fasteners shall be stainless steel (18-8
#10). The backsheet shall be aluminum not less than .014 inch thickness.
A 1 inch vent plug shall be installed in each of the four corners of the
back-sheet to minimize condensation.
The collector glazing shall be one sheet of low iron
tempered glass, with a minimum of 1/8 inch thickness (5/32 inch on SC/SP 40),
and a minimum transmissivity of 91 percent (89 on SC/SP 40). The glazing shall
be thermally isolated from the casing by a continuous EPDM gasket. There shall
be a continuous secondary silicone seal between the glass and casing capstrip to
minimize moisture from entering the casing.
The insulation shall be foil-faced polyisocyanurate foam
sheathing board of a minimum 1 ¼ inch thickness, siliconed in place to the
aluminum backsheet. Total thermal
resistance shall be a minimum of R-12. The sides and ends of the collector shall
be insulated with a minimum of 1 inch foil-faced polyisocyanurate foam sheathing
board.
The absorber shall consist of a roll-formed copper plate
of no less than .008 inch thickness. Risers shall be a minimum of ½ inch O.D.
Type M copper tubing on no more than 4 ½ inch centers continuously soldered to
the plate utilizing a non-corrosive solder paste with a melting point of 460°F.
The risers shall be brazed to 7/8 inch O. D. Type M copper manifolds utilizing a
copper phosphorous brazing alloy with no less than 15 percent silver content,
and conforming to the American Welding Society’s BCuP-5 classification.
EPDM grommets shall isolate the manifold from the aluminum casing. The
absorber plate shall be designed for 160 psig maximum operating pressure.
A) Black
Chrome (SC Series): The absorber coating shall be black chrome on nickel with a
minimum absorptivity of 95 percent and a maximum emissivity of 12 percent. The
instantaneous efficiency of the collector shall be a minimum Y-intercept of
0.714 and a slope of no less than -0.7271
(BTU/ft2hr)/F.
B) Moderately
Selective Black Paint (SP Series): The absorber coating shall be a
moderately-selective black paint with a minimum absorptivity of 94 percent and a
maximum emissivity of 56 percent. The instantaneous efficiency of the collector
shall have a minimum Y-intercept of 0.682 and a slope of no less than -0.7995
(BTU/ft2hr)/F.
Specifications subject to change without notice.
(Performance
specifications subject to testing error of +/- 3%)